Search Complete Listing of NSN (5915011219092) 5915-01-121-9092 Parts

Here on Buy Military Fasteners, we offer competitive procurement options on countless NSN parts from leading manufacturers for the benefit of our customers. On this page, you can find NSN 5915-01-121-9092 parts and supplies, including in-demand part numbers like 10B577-2, 6091203-2, RF08493-2, RF8493-2, and others. We encourage you to consider our various options as you see fit, and toward the bottom of this page, you can also locate associated parts of NSN 5915-01-121-9092 with ease. If you take interest in any available part number on our database where you wish to obtain information for procurement, fill out and submit a Request for Quote (RFQ) form through our website. By presenting our staff with important details like your target price and expected fulfillment timeframe, you can expect to receive tailored pricing options that are designed to meet your unique needs and restrictions alike. If at any time you wish to connect with one of our staff members for service, please give us a call or email at any time; we are readily available around the clock and are always happy to provide assistance and consultation through the procurement process. Experience how Buy Military Fasteners serves as a single-sourcing solution for countless needs when you connect with us today.

Item Name Filter Radio Frequency Interfere
Federal Supply Group (FSG) Electrical and Electronic Equipment Components
Federal Supply Class (FSC) 5915 Filters and Networks
National Item Identification Number (NIIN) 01-121-9092 (011219092)
NCB Code USA (01)
Manufacturer Sora Power Inc, Cisco Systems Inc, Ems Development Corporation
Part Number Manufacturer Item Name Cage Code RFQ
10B577-2 sora power inc filter radio frequency interfere 13058 RFQ
6091203-2 cisco systems inc filter radio frequency interfere 03640 RFQ
RF08493-2 ems development corporation filter radio frequency interfere 13619 RFQ
RF8493-2 ems development corporation filter radio frequency interfere 13619 RFQ

Technical Characteristics of NSN 5915011219092

MRCCriteriaCharacteristic
ABHPOVERALL LENGTH7.000 INCHES NOMINAL
ABKWOVERALL HEIGHT2.400 INCHES NOMINAL
ADAQBODY LENGTH6.250 INCHES NOMINAL
ADATBODY WIDTH6.500 INCHES NOMINAL
ADAUBODY HEIGHT2.000 INCHES MAXIMUM
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH6.375 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ4.0 TO 33.0
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH5.875 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-54.0 TO 85.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 5TH RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS0.05 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.25 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.25 2ND RADIO INTERFERENCE
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS1.25 3RD RADIO INTERFERENCE
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION1.15 VOLTS AC 6TH RADIO INTERFERENCE
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE77820
AHBPINPUT TERMINAL IDENTIFICATION10-521253-21P
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AKEJMOUNTING FACILITY SCREW THREAD SERIES DESIGNATORUNF
AKNAINCLOSURE TYPEENCASED
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 CAPTIVE SCREWS
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 CONNECTOR,RECEPTACLE INPUT 1ST FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY1 TAB W/SCREW GROUND 3RD FUNCTION
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY18 TAB W/SCREW OUTPUT 2ND FUNCTION
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE400.0 VOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION115.0 VOLTS AC 6TH RADIO INTERFERENCE 6TH FUNCTION
CQJXNOMINAL THREAD SIZE0.250 INCHES
CQRGBODY MATERIALMETAL
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE100.0 VOLTS AT SEA LEVEL
CRSTBODY SURFACE TREATMENTTIN
FEATSPECIAL FEATURES18 FUNCTIONS
STYLSTYLE DESIGNATORRECTANGULAR TERMINAL/TERMINALS ON TWO SURFACES

Relevant Components for NSN - 5915-01-121-9092, 5915011219092
5935-01-129-6228 (5935011296228) 5961-01-617-2197 (5961016172197) 5999-21-914-5435 (5999219145435) 5995-01-659-2509 (5995016592509)
5995-01-694-5736 (5995016945736) 5910-01-340-9866 (5910013409866) 5962-01-303-9106 (5962013039106) 5998-00-983-8653 (5998009838653)
5910-01-285-8016 (5910012858016) 5935-01-256-0245 (5935012560245) 5950-00-405-2915 (5950004052915) 5998-01-267-0558 (5998012670558)

Recently Viewed Parts

Submit a Quote and We'll Get Back to You Shortly

Guaranteed quotes back within 15 minutes, 24/7 x 365

Thank You for Visiting.

If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.

Request for Quote

We use cookies to ensure that we give you the best experience on our website. If you continue to use this site we will assume that you are happy with it.

bottom to top