Here on Buy Military Fasteners, we offer competitive procurement options on countless NSN parts from leading manufacturers for the benefit of our customers. On this page, you can find NSN 5950-01-067-0999 parts and supplies, including in-demand part numbers like 210016, 40-052794-01, and others. We encourage you to consider our various options as you see fit, and toward the bottom of this page, you can also locate associated parts of NSN 5950-01-067-0999 with ease. If you take interest in any available part number on our database where you wish to obtain information for procurement, fill out and submit a Request for Quote (RFQ) form through our website. By presenting our staff with important details like your target price and expected fulfillment timeframe, you can expect to receive tailored pricing options that are designed to meet your unique needs and restrictions alike. If at any time you wish to connect with one of our staff members for service, please give us a call or email at any time; we are readily available around the clock and are always happy to provide assistance and consultation through the procurement process. Experience how Buy Military Fasteners serves as a single-sourcing solution for countless needs when you connect with us today.
Item Name | Transformer Power |
Federal Supply Group (FSG) | Electrical and Electronic Equipment Components |
Federal Supply Class (FSC) | 5950 Coils and Transformers |
National Item Identification Number (NIIN) | 01-067-0999 (010670999) |
NCB Code | USA (01) |
Manufacturer | Atco Technology Inc, Northrop Grumman Systems Corporation |
Part Number | Manufacturer | Item Name | Cage Code | RFQ |
---|---|---|---|---|
210016 | atco technology inc | transformer power | 17547 | RFQ |
40-052794-01 | northrop grumman systems corporation | transformer power | 15280 | RFQ |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 2.490 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 2.510 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.177 INCHES MINIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS AND 1.197 INCHES MAXIMUM SINGLE MOUNTING FACILITY ALL CENTER GROUPINGS |
ACZB | FREQUENCY RATING | 400.0 HERTZ NOMINAL SINGLE COMPONENT |
ACZC | INPUT-OUTPUT PHASE RELATIONSHIP | THREE PHASE TO THREE PHASE SINGLE COMPONENT |
ACZD | TRANSFORMER WINDING CONNECTION TYPE | WYE-DELTA |
ACZX | WINDING SHIELDING METHOD | INTERNAL SHIELD BROUGHT OUT TO TERMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 3.020 INCHES MINIMUM AND 3.060 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.710 INCHES MINIMUM AND 1.750 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 2.830 INCHES MINIMUM AND 2.870 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 100.0 DEG CELSIUS |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 4 ALL GROUPINGS |
AXGY | MOUNTING METHOD | THREADED HOLE ALL GROUPINGS |
BPLC | WINDING FUNCTION AND QUANTITY | 1 PRIMARY SINGLE COMPONENT AND 5 SECONDARY SINGLE COMPONENT |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES ALL GROUPINGS |
CRBZ | WINDING OPERATING CURRENT | 1.7 AMPERES AC NOMINAL SINGLE COMPONENT 1ST SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 2.6 AMPERES AC NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 600.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CRBZ | WINDING OPERATING CURRENT | 900.0 MILLIAMPERES AC NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 22.6 VOLTS-AMPERES SINGLE COMPONENT 4TH SECONDARY |
CRMJ | WINDING POWER RATING | 26.9 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY |
CRMJ | WINDING POWER RATING | 27.7 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY |
CRMJ | WINDING POWER RATING | 82.8 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 115.00 AC VOLTS NOMINAL SINGLE COMPONENT SINGLE PRIMARY |
CWJS | WINDING OPERATING VOLTAGE | 17.80 AC VOLTS NOMINAL SINGLE COMPONENT 2ND SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 18.40 AC VOLTS NOMINAL SINGLE COMPONENT 3RD SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 21.80 AC VOLTS NOMINAL SINGLE COMPONENT 4TH SECONDARY |
CWJS | WINDING OPERATING VOLTAGE | 9.13 AC VOLTS NOMINAL SINGLE COMPONENT 1ST SECONDARY |
FEAT | SPECIAL FEATURES | ONE PRIMARY WINDING; FIVE SECONDARY WINDINGS |
THSD | THREAD SERIES DESIGNATOR | UNC ALL GROUPINGS |
TTQY | TERMINAL TYPE AND QUANTITY | 20 WIRE HOOK |
Relevant Components for NSN - 5950-01-067-0999, 5950010670999 | ||||
5935-01-363-1368 (5935013631368) | 5930-00-831-1493 (5930008311493) | 5962-01-696-1205 (5962016961205) | 5905-01-436-5451 (5905014365451) | |
5935-01-671-5205 (5935016715205) | 5995-01-514-6149 (5995015146149) | 5998-00-279-3996 (5998002793996) | 5955-00-249-1083 (5955002491083) | |
5995-01-165-5042 (5995011655042) | 5930-01-602-1899 (5930016021899) | 5995-01-663-8701 (5995016638701) | 5998-00-557-1668 (5998005571668) | |
If You’re Ever Looking for NSN parts Or Have an Aircraft On Ground Situation, Don’t forget That We offer Competitive Pricing and Guaranteed On-Time Delivery.
Request for Quote