MRC | Criteria | Characteristic |
---|
AAGR | CROSS-SECTIONAL SHAPE STYLE | INTERNAL,RECTANGULAR DOUBLE RIDGED EXTERNAL,RECTANGULAR DOUBLE INDENTED |
AAJD | THREAD CLASS | 2B SECOND FLANGE FIRST CONNECTION FACILITY |
AAJF | THREAD DIRECTION | RIGHT-HAND SECOND FLANGE FIRST CONNECTION FACILITY |
AHRV | TUBING WALL CONSTRUCTION STYLE | CONVOLUTE SECOND TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS FIRST TUBING SEGMENT |
AHRV | TUBING WALL CONSTRUCTION STYLE | SEAMLESS THIRD TUBING SEGMENT |
AHRW | TUBING TWIST TYPE | TWISTABLE SECOND TUBING SEGMENT |
AHSF | FLANGE QUANTITY | 2 |
AHSX | FLANGE INSIDE WIDTH | 0.688 INCHES MINIMUM ALL FLANGES AND 0.693 INCHES MAXIMUM ALL FLANGES |
AHSY | FLANGE INSIDE HEIGHT | 0.319 NOMINAL MILS ALL FLANGES AND 0.323 NOMINAL CENTIMETERS ALL FLANGES |
AHSZ | FLANGE OUTSIDE WIDTH | 1.358 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHTA | FLANGE OUTSIDE HEIGHT | 1.358 INCHES MINIMUM ALL FLANGES AND 1.390 INCHES MAXIMUM ALL FLANGES |
AHTD | FLANGE DEPTH | 0.235 INCHES MINIMUM ALL FLANGES AND 0.255 INCHES MAXIMUM ALL FLANGES |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL FIRST FLANGE SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.096 INCHES NOMINAL SECOND FLANGE SECOND CONNECTION FACILITY |
AHTN | FLANGE CONNECTING HOLE DIAMETER | 0.143 INCHES MINIMUM FIRST FLANGE FIRST CONNECTION FACILITY AND 0.149 INCHES MAXIMUM FIRST FLANGE FIRST CONNECTION FACILITY |
AHTW | VOLTAGE STANDING WAVE RATIO | 1.50 |
CMLP | THREAD QUANTITY PER INCH | 32 SECOND FLANGE ALL CONNECTION FACILITIES |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES SECOND FLANGE FIRST CONNECTION FACILITY |
CRFH | WAVEGUIDE INSIDE WIDTH | 0.691 INCHES NOMINAL |
CRLB | WAVEGUIDE INSIDE HEIGHT | 0.321 INCHES NOMINAL |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE FIRST FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 2 UNTHREADED HOLE SECOND FLANGE SECOND CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 THREADED HOLE SECOND FLANGE FIRST CONNECTION FACILITY |
CSQT | FLANGE CONNECTING FACILITY AND QUANTITY | 4 UNTHREADED HOLE FIRST FLANGE FIRST CONNECTION FACILITY |
CTCJ | FLANGE STYLE | CONTACT,DOUBLE RIDGE TYPE ALL FLANGES |
CTFD | WAVEGUIDE LENGTH | 14.440 INCHES MINIMUM AND 14.500 INCHES MAXIMUM |
FEAT | SPECIAL FEATURES | 1ST FLANGE PRESSURIZED W/SEAL AND 0.625 IN. LG SCREWS W/LOCKWASHER FOR EA MTG HOLE |
FLEX | FLEXIBILITY | FLEXIBLE SECOND TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID FIRST TUBING SEGMENT |
FLEX | FLEXIBILITY | RIGID THIRD TUBING SEGMENT |
MATT | MATERIAL | ALUMINUM ALLOY FIRST TUBING SEGMENT AND FLANGE |
MATT | MATERIAL | ALUMINUM ALLOY THIRD TUBING SEGMENT AND FLANGE |
MATT | MATERIAL | COPPER ALLOY SECOND TUBING SEGMENT |
PMLC | PRECIOUS MATERIAL AND LOCATION | FLEXGUIDE SURFACES SILVER |
PRMT | PRECIOUS MATERIAL | SILVER |
SFTT | SURFACE TREATMENT | SILVER SECOND TUBING SEGMENT ALL SURFACES |
STYL | STYLE DESIGNATOR | OFFSET BEND TYPE |
SUPP | SUPPLEMENTARY FEATURES | MARKED ONE END W/ARROW AND LETTERS OUTBD |
THSD | THREAD SERIES DESIGNATOR | UNC SECOND FLANGE FIRST CONNECTION FACILITY |
ZZZV | FSC APPLICATION DATA | ANTENNAS,WAVEGUIDES,AND RELATED EQUIPMENT |