Buy 6181559-008 Part by Amphenol Corporation with NSN 5915-01-330-0553 Today

Part Number: 6181559-008
Alternate P/N: 6181559008
Manufacturer: Amphenol Corporation
NIIN: 013300553
CAGE Code: 77820
FSG: 59 Electrical and Electronic Equipment Components
Country: USA
NCB Code: 01

Whether you are in the market for NSN parts, military and defense parts, aerospace parts, or other similar product solutions, Buy Military Fasteners is your one-stop shop with an expansive selection tracing back to premier manufacturers and entities that we trust. Thank you for taking an interest in part number 6181559-008, a Amphenol Corporation item that is listed alongside the description “Filter Radio Frequency Interfere” and the NSN 5915013300553. As part number 6181559-008 is ready for purchase on our website at any time, you are invited to fill out and submit the RFQ form provided on this page for the means of requesting a quote for your comparisons. All that we ask is that you supply us with crucial details such as your target price and expected shipping time frame, that way we can best customize a solution that caters to your unique requirements and constraints alike.

Note : We Will Not Share Your Information To Any Third Parties.

Product Details

“*” Required Fields Are Compulsory

Contact Information

   * By clicking this box, I acknowledge that I have read and accept the ASAP Semiconductor Terms and Conditions and agree that all quotes and purchase orders are exclusively subject to the ASAP Semiconductor Terms and Conditions.
  • I consent to receive email communications from ASAP Semiconductor and can unsubscribe at any time.
  • ASAP Semiconductor is a wholly independent aftermarket parts distributor.
  • This website is intended for quotations based on part numbers only. Please DO NOT submit drawings, technical data, or other specifications through this portal.

Disclaimer: This is a quotation for the goods listed above. This quotation is meant as an estimate and does not reflect a final bill or invoice. All quotations are subject to change until acceptance by ASAP Semiconductor of a binding Purchase Order, and quotations may be withdrawn or revised at the sole discretion of ASAP Semiconductor. This quotation is subject to the ASAP Semiconductor Terms & Conditions available at https://www.asapsemi.com/terms-conditions.aspx . All United States Government and Department of Defense bids are quoted as CAGE code 6RE77 from ASAP Semiconductor’s Anaheim, California facility. Any quotation from ASAP Semiconductor without 6RE77 is void.

Upload RFQ SHEET

As customers explore our vast selection, they can take advantage of services like our CAGE Code search features or database filters to quickly locate products of interest for purchase. For example, part number 6181559-008 is listed alongside the NSN 5915-01-330-0553, meaning that it also belongs to FSC 5915 Filters and Networks. With this in mind, kick off procurement with us today with assurance that we can even fulfill your most difficult needs. 

NSN Information for Part Number 6181559-008 with NSN 5915-01-330-0553, 5915013300553

NSNFSCNIINCLSHazmatDEMILCancelled NSN
5915-01-330-0553

Item PartTypeName:

FILTER,RADIO FREQUENCY INTERFERE

59150133005530P
CIICHCCESDPMICCriticalityENAC
UG
Part NumberISCRNVCRNCCHCCMSDSSADC
6181559-008695

Characteristics Data of NSN 5915-01-330-0553, 5915013300553

MRCCriteriaCharacteristic
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 1ST RADIO INTERFERENCE 1ST FUNCTION400.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 4TH RADIO INTERFERENCE 4TH FUNCTION5.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE 5TH FUNCTION
AHCGMAXIMUM TEMP RISE25.0 DEG CELSIUS
AKNAINCLOSURE TYPEHERMETICALLY SEALED
CBBLFEATURES PROVIDEDMOISTURE RESISTANT AND SHOCK RESISTANT
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 1ST RADIO INTERFERENCE AND 800.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION250.0 VOLTS AC 2ND RADIO INTERFERENCE AND 800.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
ABMKOVERALL WIDTH1.710 INCHES NOMINAL
AEBYDISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH1.271 INCHES NOMINAL
AEHADISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY WIDTH1.271 INCHES NOMINAL
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 6TH RADIO INTERFERENCE 6TH FUNCTION400.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 3RD RADIO INTERFERENCE 3RD FUNCTION5.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 6TH RADIO INTERFERENCE 6TH FUNCTION5.0 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION2.5 VOLTS AC 3RD RADIO INTERFERENCE AND 8.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION2.5 VOLTS AC 6TH RADIO INTERFERENCE AND 8.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBNINPUT TERMINAL MANUFACTURER CODE59610
AHBSOUTPUT TERMINAL MANUFACTURER CODE5961059610
AHCJFULL LOAD INSERTION LOSS FREQUENCIES IN MEGAHERTZ0.0 AND 0.1 AND 1.0 AND 10.0 AND 100.0 AND 1000.0
AXHRMOUNTING FACILITY TYPE AND QUANTITY4 UNTHREADED HOLE ALL FUNCTIONS
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION250.0 VOLTS AC 3RD RADIO INTERFERENCE AND 800.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION
CQRGBODY MATERIALALUMINUM
CRDCMAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE1.2 KILOVOLTS AT SEA LEVEL
CRSTBODY SURFACE TREATMENTCADMIUM
FEATSPECIAL FEATURESTHIRTY-TWO FILTERED FUNCTIONS WITH X-TYPE INSERT POSITION
STYLSTYLE DESIGNATORFILTER CONNECTOR
ABKWOVERALL HEIGHT1.710 INCHES NOMINAL
AEBVUNTHREADED MOUNTING HOLE DIAMETER0.125 INCHES NOMINAL
AECRVIBRATION RESISTANCE RANGE IN HERTZ10.0 TO 500.0
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION50.0 OHMS 1ST RADIO INTERFERENCE 1ST FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION50.0 OHMS 2ND RADIO INTERFERENCE 2ND FUNCTION
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION50.0 OHMS 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 2ND RADIO INTERFERENCE 2ND FUNCTION400.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 4TH RADIO INTERFERENCE 4TH FUNCTION400.0 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 2ND RADIO INTERFERENCE 2ND FUNCTION5.0 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 1ST RADIO INTERFERENCE AND 8.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION2.5 VOLTS AC 5TH RADIO INTERFERENCE AND 8.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE 3RD FUNCTION
AHCKFULL LOAD MINIMUM INSERTION LOSS AT SPECIFIED FREQUENCY IN DECIBELS3.0 AND 10.0 AND 50.010.0 AND 50.0 AND 50.0
CQDWFUNCTIONAL TERMINAL TYPE AND QUANTITY32 FRICTION W/GROUNDING STRAP AND PIN INPUT-OUTPUT ALL FUNCTIONS
CQDZMAXIMUM DIELECTRIC WITHSTANDING AC RMS VOLTAGE1.2 KILOVOLTS AT SEA LEVEL
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION250.0 VOLTS AC 4TH RADIO INTERFERENCE AND 800.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION250.0 VOLTS AC 5TH RADIO INTERFERENCE AND 800.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION
CQGCOPERATING VOLTAGE RATING AND TYPE PER FUNCTION250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION250.0 VOLTS AC 6TH RADIO INTERFERENCE AND 800.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION
ABHPOVERALL LENGTH2.187 INCHES NOMINAL2.187 INCHES NOMINAL
AFGAOPERATING TEMP RANGE-55.0 TO 125.0 DEG CELSIUS
AHAQSOURCE IMPEDANCE RATING PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION50.0 OHMS 4TH RADIO INTERFERENCE 4TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION50.0 OHMS 5TH RADIO INTERFERENCE 5TH FUNCTION
AHASLOAD IMPEDANCE PER FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION50.0 OHMS 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 3RD RADIO INTERFERENCE 3RD FUNCTION400.0 3RD RADIO INTERFERENCE 3RD FUNCTION
AHBBPOWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ400.0 5TH RADIO INTERFERENCE 5TH FUNCTION400.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 1ST RADIO INTERFERENCE 1ST FUNCTION5.0 1ST RADIO INTERFERENCE 1ST FUNCTION
AHBCOPERATING CURRENT RATING PER FUNCTION IN AMPS5.0 5TH RADIO INTERFERENCE 5TH FUNCTION5.0 5TH RADIO INTERFERENCE 5TH FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION2.5 VOLTS AC 2ND RADIO INTERFERENCE AND 8.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBEMAXIMUM VOLTAGE DROP PER FUNCTION2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION2.5 VOLTS AC 4TH RADIO INTERFERENCE AND 8.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE 2ND FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE 4TH FUNCTION
AHBLPRINCIPAL CIRCUITRY TYPE PER FUNCTIONINDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE 6TH FUNCTION
AHBPINPUT TERMINAL IDENTIFICATIONMIL-C-26482
AHBTOUTPUT TERMINAL IDENTIFICATIONMIL-C-26482
PMLCPRECIOUS MATERIAL AND LOCATIONCONTACT SURFACES GOLD
PRMTPRECIOUS MATERIALGOLD

Related NSN Components of 6181559 008